Call us: 805-383-1234   

Power Supplies : Open Frame - U-Channel : SNP-Z30D-2 - 300W U-Channel with Active PFC at eUrasia Power

Power Supplies : Open Frame - U-Channel


SNP-Z30D-2
300W U-Channel with Active PFC

View Specifications in PDF Format
300W U-Channel with Active PFC
300W U-Channel with Active PFC

 

Skynet`s new SNP-Z3 series packs 300W of high efficiency power in a 1U package while maintaining excellent thermal performance. This is made possible by Skynet`s patent pending soft-switching topology which offers up to 87% efficiency in an offline (AC-DC) switcher!

300W Continuous output power in a 1U form factor
Up to 90% efficiency!
Active power factor correction
Meets IEC-1000-3-2 harmonics
EMI: EN55022 Class B
Safety UL 60950; CSA 22.2 No. 234; EN60950
5 x 9 x 1.6 inch
127 x 228.6 x 40.6 mm
Output+3.3V+5V+12V
Max Load30A / 40A PK20A / 25A PK8A / 10A PK
Regulation+-1%+-1%+-5%
Ripple50mV50mV100mV
View Specifications in PDF Format
Input VAC
Voltage, V 90-264 continuous
Frequency, Hz 47-63
Current, A 8A @ 120V / 4A @ 240V
Power Factor 0.95 minimum at max load
Harmonics EN61000-3-2
Cooling Free air convection for single output; 30CFM force
Power Good TTL compatible
Holdup Time 20ms, nominal line, full load
Transient Return to 1% in 1ms, 20% load step at 0.5A/us slew rate
Efficiency 68% at full load, typical
Shorted output No damage
Over Load Protection Auto-recovery
Short Circuit Protection Auto-recovery
Over Voltage Protection Latch-off
EMS EN61000-4-2,-3,-4,-5,-6,-8,-11
Temperature 0 to 50 degrees C
EMI EN55022
Safety Agency UL 60950, CSA 22.2 No. 234, EN60950

Notes
Go to top
1. The total output current is rated load with free air convection and maximum load.
2. Each output is checked at the factory to be within voltage accuracy with a 60% rated load condition.
3. Line regulation is defined by changing the input voltage 10% from nominal line at rated load.
4. Load regulation is defined by changing the output load 40% from 60% of the rated load while another output is set to 60% of rated load.
5. Ripple & noise is measured at rated load and nominal line by using a 15MHz bandwidth limited oscilloscope with each output terminated by a 0.47 uF capacitor.
6. Hold up time is measured from the end of the last charging pulse to when the main output drops down to 95% output voltage.
7. Efficiency is measured at rated load.

 

 
Click here to view a printer friendly mechanical drawing.
300W U-Channel with Active PFC


Return to product index

The information and specifications contained in this data sheet are believed to be accurate at the time of publication. If errors are found, they will be corrected. Consequently, specifications may be subject to change without notice.