Model O/P Voltage O/P Current Watt
uM60-1012 12.0V 5.00A 60W
uM60-1012 15.0V 4.00A 60W
uM60-1012 19.0V 3.15A 60W
uM60-1012 24.0V 2.50A 60W
uM60-1012 48.0V 1.25A 60W
Note
Voltage : 100-240VAC
Line Frequency : 50-60Hz
Current : 1.5 A Max.
Protection:Internal Primary Current Fuse
Output
Load Regulation : ±5% ( Typical )
Ripple & Noise : 1% Vp-p Max. for Output Voltage @ Full Load
Transient Response : 0.5mS for 50% Load Change Typical
Hold-up Time : 10mS @ Full Load
Protection: Short Circuit Protection / Over Voltage
Protection / Over Current Protection /
Safety Approvals
CB / UL / cUL / FCC / CE / LPS
Electrical
Topology : Switching Flyback
Dielectric Withstand : 3000VAC Primary – Secondary
Leakage Current : 0.25mA
Efficiency : DoE Level VI, Energy Star, ErP
Stage 2, CoC Tier 2, NRCan & GEMS Level VI Certified
EMC Standards: EN55032 , EN61000-3-2,3
EN55024
MTBF : 300,000 Calculated Hours at 25ºC , by Telcordia SR-332
Environmental
Operating Temperature : 0 to + 40ºC
Storage Temperature : -20 to + 80ºC
Relative Humidity : Operating : 20 to 80% RH
Storage : 10 to 90% RH
Cooling : Natural Convection Cooling
Keywords
Tier 2, NRCan & GEMS Level VI
No Load Power Consumption Less Than 0.15W
Features
■ 100-240VAC Universal Input
■ Regulated Output With Low Ripple Noise
■ Safety Agency Requirements and EMI/EMS Certified
■ Private Label Marking Available
■ Modified and Custom Design Available
■ 1 Year Warranty