CEC, DoE Level VI, Energy Star, ErP Stage 2
No Load Power Consumption Less Than 0.075W
Features
■ ANSI/AAMI/IEC/EN ES60601-1:2012 (60601 edition 3.1)
■ Means of Protection: 2 X MOPP
■ Touch Current : < 100μA
■ Meet UL60950-1 , EN60950
■ 100-240VAC Universal Input
■ Regulated Output With Low Ripple Noise
■ Modified and Custom Design Available
■ 2 Years Warranty
Size
L65 x W45 x H24 (mm
Output
24.0V @0.50 A
Specification
Input | VAC |
Voltage, V | 100-240VAC |
Frequency, Hz | 50-60Hz |
Current, A | 12W : 0.29A-0.17A, 24W : 0.55A-0.3A |
Power Factor | N/A |
Harmonics | N/A |
Cooling | Natural Convection Cooling |
Power Good | N/A |
Holdup Time | 10 mS min. @ full load |
Transient | 0.5mS for 50% Load Change Typical |
Efficiency | DoE Level VI, Energy Star, ErP Stage 2 Certified |
Shorted output | N/A |
Over Load Protection | N/A |
Short Circuit Protection | auto-recovery |
Over Voltage Protection | auto-recovery |
EMC | EN55032 EN61000-3-2,3 EN55024 |
Temperature | 0 to 50 deg C |
EMI | N/A |
Safety Agency | CB / UL / cUL / FCC / CE / T-mark(TUV) / PSE |