SNP-A06 series is designed for both medical and ITE applications. It features a no-load input power less than 1 watt and efficiencies ranging from 80~85% depending on the model. This makes it compatible with worldwide green power requirements.
This series features low leakage current and FCC & VDE class B EMI. Meanwhile, it complies with a wide variety of safety regulations so that it can be used in Medical, Industrial, Information Technology or other equivalent applications.
Features
• High Efficiency up to 87%
• Small size / high power density
• FCC Class B & CISPR class B
• Medical and ITE Agency Approvals
• UL60601, UL60950,
• CSA 22.2 No. 601.1, No. 60950-1 (cUL)
• TÜV EN60950, 60601-1
• EN61000-4-2,-3,-4,-5,-6,-11
• Small size / high power density
• FCC Class B & CISPR class B
• Medical and ITE Agency Approvals
• UL60601, UL60950,
• CSA 22.2 No. 601.1, No. 60950-1 (cUL)
• TÜV EN60950, 60601-1
• EN61000-4-2,-3,-4,-5,-6,-11
Size
2..56 x 5.31 x 1.57 inch
65 x 135 x 40 mm
65 x 135 x 40 mm
DC Outputs
Output | 48V |
Rated Load | 1.25A / 1.5A pk |
Regulation | ±1% |
Ripple | 50mV |
Specifications
Input | VAC |
Voltage, V | 90-264 continuous |
Frequency, Hz | 47-63 |
Current, A | inrush I <35A at 115VAC; <70A at 230VAC |
Power Factor | N/A |
Harmonics | N/A |
Cooling | Free air convection |
Power Good | N/A |
Holdup Time | 10 mS minimum @ 115 VAC, full load |
Transient | N/A |
Efficiency | 80%~87% at full load depending on model |
Shorted output | No damage, auto-recovery |
Over Load Protection | auto-recovery |
Short Circuit Protection | auto-recovery |
Over Voltage Protection | auto-recovery |
EMS | EN61000-4-2, -3, -4, -5, -6, -11 |
Temperature | 0° C to 40° C |
EMI | FCC class B; CISPR22 level |
Safety Agency | UL60601-1, UL 60950-1(cUL), TUV EN60950-1, EN60601-1 |
Notes
1. Output can provide up to peak load when the power supply starts up. Continuously exceeding the rated load is not allowed.
2. At factory, in 60% rated load condition, each output is checked to be within voltage accuracy.
3. Line regulation is defined by changing ±10% of input voltage from nominal line at rated load.
4. Load regulation is defined by changing ±40% of measured output load from 60% rated load.
5. Ripple & noise is measured by using 15MHz bandwidth limited oscilloscope and terminated each output with a 0.47uF capacitor at rated load and nominal line.
6. Hold up time is measured from the end of the last charging pulse to the time which the main output drops down to low limit of main output at rated load and nominal line.
7. Efficiency is measured at rated load, and nominal line.
8. Packing:
Net weight: 220 g approx. / unit
Gross weight: 15.5 kg approx. / carton, 60 units / carton
Carton size (mm): 512 (L) x 354 (W) x 343 (H)
2. At factory, in 60% rated load condition, each output is checked to be within voltage accuracy.
3. Line regulation is defined by changing ±10% of input voltage from nominal line at rated load.
4. Load regulation is defined by changing ±40% of measured output load from 60% rated load.
5. Ripple & noise is measured by using 15MHz bandwidth limited oscilloscope and terminated each output with a 0.47uF capacitor at rated load and nominal line.
6. Hold up time is measured from the end of the last charging pulse to the time which the main output drops down to low limit of main output at rated load and nominal line.
7. Efficiency is measured at rated load, and nominal line.
8. Packing:
Net weight: 220 g approx. / unit
Gross weight: 15.5 kg approx. / carton, 60 units / carton
Carton size (mm): 512 (L) x 354 (W) x 343 (H)