Skynet’s SNP-G20 Series is a 3″ x 5″ open frame power supply with an amazing power density of 9.4 watts per cubic inch plus active PFC. The 3” x 5” form factor has been an industry standard for more than 10 years. Initially the power density was around 2 watts per cubic inch then hovered around 3 watts per cubic inch for quite some time. Now the SNP-G20 series in 3″ x 5″ form factor is undoubtedly the current state-of-the-art. With built-in PFC
Features
• 12V @ 16.5A, 25A max, 33A peak
• With built-in PFC
• Only 1.47 inch height
• 9.4 Watt per cubic inch
• With ITE & Medical safety
• Efficiency between 82% to 88%
• Operation from 0°C to 70°C by convection
• With built-in PFC
• Only 1.47 inch height
• 9.4 Watt per cubic inch
• With ITE & Medical safety
• Efficiency between 82% to 88%
• Operation from 0°C to 70°C by convection
Size
3 x 5 x 1.47 inch
76.2 x 127 x 36.1 mm
76.2 x 127 x 36.1 mm
DC Outputs
| Output | +12 VDC |
| Max Load | 25A / 33A pk. |
| Regulation | ±1% |
| Ripple | ±1% |
Specifications
| Input | VAC |
| Voltage, V | 90 to 264 VAC |
| Frequency, Hz | 47 to 63 |
| Current, A | inrush I <30A at 115VAC; <60A at 230VAC |
| Power Factor | Active PFC |
| Harmonics | EN61000-3-2, Class D |
| Cooling | Free air convection for 200W 300W w forced air |
| Power Good | N/A |
| Holdup Time | 20 mS typical at rated load and 115VAC |
| Transient | N/A |
| Efficiency | Energy Star V6, ErP |
| Shorted output | Protected |
| Over Load Protection | Auto-recovery |
| Short Circuit Protection | Auto-recovery |
| Over Voltage Protection | Latch-off |
| EMS | EN61000-4-2, -3, -4, -5, -6, -8, -11 |
| Temperature | -20 to +70 degrees C |
| EMI | EN55022 B, EN61000-3-3 |
| Safety Agency | UL/CSA/EN60950-1,2nd Edition ANSI/AMMI/CSA/EN60601-1, 3rd Edition CB Report, CE Mark, RM rpt |
Notes
1. Standby Power Consumption with System:
- For computers and displays, ENERGY STAR in U.S. and ErP regulation in Europe require the input power should be less than 0.5W at standby mode.
2. Output Load:
- 200W for convection cooling; 300W for forced air cooling.
3. Peak Load Duration:
- Peak 400W can last for 5 sec.
4. Isolation Grade:
- Primary Ground : 1MOPP (1500Vac)
- Primary Secondary : 2MOPP (4000Vac)
- Secondary Ground : 1MOPP (1500Vac)
5. Leakage Current:
- Earth leakage current < 300uA
- Touch current < 100uA
6. EMI Grounding:
- If there is a metal sheet under the power supply, connect the EMI ground to the metal sheet.
7. Model Selection:
- Most of power supplies will create audible burst sound at light load, if the application wants to meet input power < 0.5W at standby mode.
- SNP-G20x is for ITE application which requires standby mode.
- SNP-G20x-A is for ITE application but without burst sound and no standby mode.
- SNP-G20x-M is for medical application which requires standby mode.
- SNP-G20x-MA is for medical application but without burst sound and no standby mode