Features
5.8 Watts per cubic inch
• Both Medical & ITE Safety Approvals
• Efficiency between 85% to 90%
• Operation from -20°C to +85°C by convection
• Starts into a 30,000 microfarad capacitive load
• Only 1.38 inch height
• Remote Sense
• Safety Agency Approvals
UL 60950-1, UL 60601-1
CSA C22.2 No. 60950.1, No. 60601-1, TUV EN60950-1, EN60601-1, CSA 601-1, EN60601-1
• EMI
FCC class “B”
CISPR22 level “B”
• EMS
EN61000-4-2,-3,-4,-5,-6,-11
• Both Medical & ITE Safety Approvals
• Efficiency between 85% to 90%
• Operation from -20°C to +85°C by convection
• Starts into a 30,000 microfarad capacitive load
• Only 1.38 inch height
• Remote Sense
• Safety Agency Approvals
UL 60950-1, UL 60601-1
CSA C22.2 No. 60950.1, No. 60601-1, TUV EN60950-1, EN60601-1, CSA 601-1, EN60601-1
• EMI
FCC class “B”
CISPR22 level “B”
• EMS
EN61000-4-2,-3,-4,-5,-6,-11
Size
3 x 5 x 1.3 inch
76.2 x 127 x 33 mm
76.2 x 127 x 33 mm
Specifications
| Input | VAC |
| Voltage, V | 90 to 264 |
| Frequency, Hz | 47 to 63 |
| Current, A | inrush I <30A at 115VAC; <60A at 230VAC |
| Power Factor | Active PFC |
| Harmonics | EN61000-3-2 |
| Cooling | Free Air Convection for 120W w/ 18CFM forced air f |
| Power Good | N/A |
| Holdup Time | 20 mS typical at rated load and 115VAC |
| Transient | consult factory |
| Efficiency | 85%~90% depending on model |
| Shorted output | Protected auto recovery |
| Over Load Protection | Auto-recovery |
| Short Circuit Protection | Auto-recovery |
| Over Voltage Protection | Latch-off |
| EMS | EN61000-4-2, -3, -4, -5, -6, -11 |
| Temperature | -20°C to +85°C; derating: 2.5% / °C > 50°C |
| EMI | EN55022 B, FCC B |
| Safety Agency | UL 60950-1, UL 60601-1 CSA C22.2 No.60950.1, No. 60601-1,TUV EN60950-1, EN60601-1 |
DC Outputs
| Output | 12V |
| Rated Load | 10A /12.5A pk |
| Regulation | ±1% |
| Ripple | 120mV |