These new 70W, 3″ x 5″, medical grade power supplies are designed with Skynet`s patented Ring-Free ZVS technology to ensure high efficiency and compact size.
This series features Active PFC; low leakage current and FCC & VDE class B EMI. Meanwhile, it complies with a wide variety of safety regulations so that it can be used in Medical, Industrial, Information Technology or other equivalent applications.
Features
• Low leakage current
• FCC & EN55011 class “B”; EN61000-3-2 class “A”
• UL2601, CSA 22.2 NO.601.1, EN 60601-1
• Up to 90% efficiency
• Active power factor correction
• Meets IEC-1000-3-2 harmonics
• FCC & EN55011 class “B”; EN61000-3-2 class “A”
• UL2601, CSA 22.2 NO.601.1, EN 60601-1
• Up to 90% efficiency
• Active power factor correction
• Meets IEC-1000-3-2 harmonics
Size
3 x 5 x 1.18 inch
76.2 x 127 x 30 mm
76.2 x 127 x 30 mm
Specifications
Input | VAC |
Voltage, V | 90 to 264 |
Frequency, Hz | 47 to 63 |
Current, A | inrush I <30A at 115VAC; <60A at 230VAC |
Power Factor | Active PFC |
Harmonics | EN61000-3-2 |
Cooling | Free air convection for 100W 18 CFM forced air |
Power Good | consult factory |
Holdup Time | 20 mS typical at rated load and 115VAC |
Transient | consult factory |
Efficiency | 80%~90% depending on model |
Shorted output | Protected |
Over Load Protection | Auto-recovery |
Short Circuit Protection | Auto-recovery |
Over Voltage Protection | Latch-off |
EMS | EN61000-4-2, -3, -4, -5, -6, -11 |
Temperature | 0 to 50 degrees C |
EMI | EN55022 |
Safety Agency | UL 60950, CSA 22.2 No. 234 and EN60950 |
DC Outputs
Output | +12 VDC | 5V |
Max Load | 5.6A / 9A pk | 0.5A |
Regulation | +/-1% | +/-1% |
Ripple | 120mV | 50mV |
Notes
1. The total output current is rated load with free air convection and maximum load. 2. Each output is checked at the factory to be within voltage accuracy with a 60% rated load condition. 3. Line regulation is defined by changing the input voltage ±10% from nominal line at rated load. 4. Load regulation is defined by changing the output load ± 40% from 60% of the rated load while another output is set to 60% of rated load. 5. Ripple & noise is measured at rated load and nominal line by using a 15MHz bandwidth limited oscilloscope with each output terminated by a 0.47 uF capacitor. 6. Hold up time is measured from the end of the last charging pulse to when the main output drops down to 95% output voltage. 7. Efficiency is measured at rated load. |