Skynet`s new SNP-Z3 series packs 300W of high efficiency power in a 1U package while maintaining excellent thermal performance. This is made possible by Skynet`s patent pending soft-switching topology which offers up to 87% efficiency in an offline (AC-DC) switcher!
Features
• 300W Continuous output power in a 1U form factor
• Up to 90% efficiency!
• Active power factor correction
• Meets IEC-1000-3-2 harmonics
• EMI: EN55022 Class B
• Safety UL 60950; CSA 22.2 No. 234; EN60950
• Up to 90% efficiency!
• Active power factor correction
• Meets IEC-1000-3-2 harmonics
• EMI: EN55022 Class B
• Safety UL 60950; CSA 22.2 No. 234; EN60950
Size
5 x 9 x 1.6 inch
127 x 228.6 x 40.6 mm
127 x 228.6 x 40.6 mm
Specifications
Input | VAC |
Voltage, V | 90-264 continuous |
Frequency, Hz | 47-63 |
Current, A | 8A @ 120V / 4A @ 240V |
Power Factor | 0.95 minimum at max load |
Harmonics | EN61000-3-2 |
Cooling | Free air convection for single output; 30CFM force |
Power Good | TTL compatible |
Holdup Time | 20ms, nominal line, full load |
Transient | Return to 1% in 1ms, 20% load step at 0.5A/us slew rate |
Efficiency | 68% at full load, typical |
Shorted output | No damage |
Over Load Protection | Auto-recovery |
Short Circuit Protection | Auto-recovery |
Over Voltage Protection | Latch-off |
EMS | EN61000-4-2,-3,-4,-5,-6,-8,-11 |
Temperature | 0 to 50 degrees C |
EMI | EN55022 |
Safety Agency | UL 60950, CSA 22.2 No. 234, EN60950 |
DC Outputs
Output | 3.3V | 5V | +12V |
Max Load | 30A / 40A PK | 20A / 25A PK | 8A / 10A PK |
Regulation | +/-1% | +/-1% | +/-5% |
Ripple | 50mV | 50mV | 100mV |
Notes
1. The total output current is rated load with free air convection and maximum load.
2. Each output is checked at the factory to be within voltage accuracy with a 60% rated load condition.
3. Line regulation is defined by changing the input voltage ±10% from nominal line at rated load.
4. Load regulation is defined by changing the output load ± 40% from 60% of the rated load while another output is set to 60% of rated load.
5. Ripple & noise is measured at rated load and nominal line by using a 15MHz bandwidth limited oscilloscope with each output terminated by a 0.47 uF capacitor.
6. Hold up time is measured from the end of the last charging pulse to when the main output drops down to 95% output voltage.
7. Efficiency is measured at rated load.
2. Each output is checked at the factory to be within voltage accuracy with a 60% rated load condition.
3. Line regulation is defined by changing the input voltage ±10% from nominal line at rated load.
4. Load regulation is defined by changing the output load ± 40% from 60% of the rated load while another output is set to 60% of rated load.
5. Ripple & noise is measured at rated load and nominal line by using a 15MHz bandwidth limited oscilloscope with each output terminated by a 0.47 uF capacitor.
6. Hold up time is measured from the end of the last charging pulse to when the main output drops down to 95% output voltage.
7. Efficiency is measured at rated load.