The eU80 series of AC/DC switching mode power supplies provide 80 Watts of continuous output power. All supplies are UL 94V-0 compliant, include IEC-320-C14 input for worldwide applications. All models meet FCC Part- 15 class B and CISPR-22 class B emission Limits and are designed to comply with UL, C-UL, TUV and CE requirements. All units are 100% burned in and tested.
Features
• Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
• IEC-320-C14 Input Inlet
• Single to Quad Output
• Output Voltage Available From 3 VDC Thru 48 VDC
• Optional Output Connector (See appendix)
• Input Surge Current, Over Voltage and Over Load protection
• Splash proof
• Class I Insulation
• Two Years Warranty
• IEC-320-C14 Input Inlet
• Single to Quad Output
• Output Voltage Available From 3 VDC Thru 48 VDC
• Optional Output Connector (See appendix)
• Input Surge Current, Over Voltage and Over Load protection
• Splash proof
• Class I Insulation
• Two Years Warranty
Size
3.1 x 6.6 x 1.25 inch
78.5 x 168 x 44.5 mm
78.5 x 168 x 44.5 mm
DC Outputs
Output, V | +5 | +15 | -15 |
Max Load, A | 6 | 2.125 | 0.208 |
Regulation, % | +/-5% | +/-5% | +/-5% |
Ripple, mV | 100 | 240 |
Specifications
Input | VAC |
Voltage, V | 90-264 continuous |
Frequency, Hz | 47-63 |
Current, A | 1.5A at 90VAC, 0.75A at 180 VAC |
Power Factor | N/A |
Harmonics | N/A |
![]() |
|
Cooling | Free air convection |
Power Good | N/A |
Holdup Time | 16 mS minimum @ 115 VAC, full load |
Transient | N/A |
Efficiency | 75% typical at full load |
Shorted output | No damage, auto-recovery |
Over Load Protection | See datasheet |
Short Circuit Protection | auto-recovery |
Over Voltage Protection | auto-recovery |
EMS | Consult Factory |
Temperature | 0 to 40 deg C |
EMI | CISPR / FCC class B |
Safety Agency | UL1950, CSA C22.2 and EN60950 with C.B. Certificate |
Notes
1. Ripple & Noise – Use 20 M Hz frequency bandwidth oscilloscope.
2. Add 0.1Uf / 47uF capacitors at output connector terminal for Ripple & Noise test.
3. Ripple Noise test condition: 90V / 60Hz, output 3.6A.
4. Ripple with spike noise <=300 mV p-p.
2. Add 0.1Uf / 47uF capacitors at output connector terminal for Ripple & Noise test.
3. Ripple Noise test condition: 90V / 60Hz, output 3.6A.
4. Ripple with spike noise <=300 mV p-p.